PCGH-3R 4-Way Cassette

The Polar Air PCGH-3R 4-Way Cassette fan coil delivers up to 15 kW of heating and cooling in a compact design for restricted ceiling spaces.

It features direct front panel access and valve connection, plus a “plug & play” control box for easy installation and service, and energy-efficient EC motors.

With quiet operation and 4-way air distribution, this hydronic cassette is ideal for healthcare, commercial, and education applications like hospitals, supermarkets, gyms, and schools.

5 sizes available · 2-pipe or 4-pipe models

Advantages

Polar Air fan coil feature icon for heating and cooling
Heating & Cooling

One of the highest certified capacities on the market with a heat/cool capacity of up to 15 kW.

Ideal for various applications, including healthcare and commercial spaces like hospitals, shopping malls, gyms and airport terminals.

Polar Air fan coil feature icon for air quality
Airflow

The 4-way air design means supply air covers the room evenly for uniform temperatures and fewer hot/cold spots.

Plus adjustable louvers (only available with I-Type Control), let you aim airflow to suit the room layout and avoid drafts on occupants.

Polar Air fan coil feature icon for condensate pump
Condensate

Integrated Sauermann pump with nominal 1200 mm (47") rated lift removes excess water efficiently to prevent leaks.

It also helps to control indoor air humidity, protects ceiling finishes, and keeps long-term maintenance to a minimum.

Polar Air slim compact fan coil design
Sensitive Design

Slim, decorative panel casing in RAL 9010 integrates neatly into ceilings and suits a wide range of interiors.

Plus an optional G4 (MERV 8) filter upgrade captures finer particles, supporting cleaner air quality in environments that need it like healthcare.

Polar Air fan coil feature icon for 2 and 4 pipes systems
Models

Includes both a 2-pipe and 4-pipe model, and available in 5 sizes to suit larger applications like hospitals.

The 4-pipe allows heating in one area and cooling in another simultaneously, ideal for buildings with varied thermal loads like north/south-facing zones or occupancy patterns.

Polar Air fan coil feature icon for easy installation and maintenance
Installation & Maintenance

Direct front panel access and valve connection with a "plug & play" control box makes installation easy.

Supplied ready to install, cutting time and cost, with internal/external drain pan, NBR insulation, integrated Sauermann condensate pump with 1200 mm (47") nominal rated lift, and G2 (MERV4) filter. With I-Type Control the Infrared Handset is also included.

Polar Air PCGH-3R 4-way cassette fan coil installed in the ceiling

Capacities

Metric

🍃 Airflow: 190 – 2750 m3/h

❄️ Cooling: 1.1 – 15 kW

☀️ Heating: 1.3 – 14.8 kW

🔊 Sound pressure: from 26 dBA*

Imperial

🍃 Airflow: 118 – 1618 CFM

❄️ Cooling: 4125 – 50990 BTU/Hr | 0.3 – 4.2 Ton

☀️ Heating: 6495 – 79266 BTU/Hr | 0.5 – 6.6 Ton

🔊 Sound pressure: from 26 dBA*

* Sound pressure level measured at 1 m distance in a reverberation test room with the minimum volume of 200 m3.

  • Compatible with renewable energy systems – works with solar thermal collectors, heat pumps, and other low-temperature sources for higher energy savings.
  • Durable coil design – copper tubes and headers mechanically expanded into corrugated aluminum fins, pressure-tested up to 35 bar with a 16-bar operating limit.
  • 0–10 VDC EC motordelivers up to 30% energy savings compared to AC motors, with smoother speed control, quieter operation, and lower running costs.
  • Manual air vent + water purge valve – enables quick and efficient system bleeding for hassle-free maintenance.
  • Internal drain pan – safely collects and channels condensate, protecting interiors from leaks, water damage, and moisture issues.
  • Integrated Sauermann condensate pump (with nominal 1200 mm (47”) rated lift) – automatically removes collected water, reducing installation time and costs by eliminating an external pump.
  • 5 mm (0.2”) NBR insulation – minimizes energy loss and prevents condensation for long-lasting efficiency.
  • G2 (MERV 4) filter – captures dust and larger particles to improve indoor air quality and protect the coil.
  • Infrared handset – included with I-Type control for convenient, user-friendly operation.
  • I-Type Controllers: Infrared Handset or Wired Wallpad
  • Valves: preassembled HYDRO+ VALVE Kit with 2/3-way body valve, on-off/modulating actuator (24V or 110-240V), BSPT or NPT connectors, connection piping kit, 2x shut-off valves, strainer and manual balancing valve
  • Filter: G4 (MERV 8)
  • Electric heater: up to 4 kW
  • Ducts: ABS branch duct flange
  • Flanges: ABS fresh air intake (up to 30%) for sensitive spaces where IAQ is important
  • Integrated transformer: converts from 230V to 24V for valve and thermostat compatibility
  • Disconnect switch: integrated in control box
  • Customization: available upon request (minimum order quantities apply)

Polar Air Control Logic

Polar Air fan coil units provide exceptional control flexibility to meet various application needs. Choose between two types of PCBs.

Exclusively developed by Polar Air for intelligent control that includes our ADBS technology for ΔT management and group control. Configuration for 2- and 4-pipe models.

Available through ModBus, or compatible with Polar Air Wired Wallpad or Infrared Handset.

Polar Air fan coil feature icon for programming

24/7 programming

Automatic three speed fan function of Polar Air fan coils.

Auto & 3-Speed functions

Polar Air fan coil feature icon for sleep mode

Sleep function

Polar Air fan coil feature icon for auto restart

Auto-Restart function

Polar Air fan coil feature icon for dehumidification and latent cooling

Dehumidification mode

Polar Air fan coil feature icon for adjustable swing louver

Adjustable swing louver positioning

Polar Air fan coil feature icon for condensate pump

Condensate drain pump control

Polar Air fan coil feature icon for error diagnostics

Error diagnostics on unit LED display or Wired Wallpad

Polar Air fan coil feature icon for integrated valves

Valve control

Polar Air fan coil feature icon for dry contact on off control

Dry contact for On/Off applications

Polar Air fan coil feature icon for electric heater

Electric heater control

Polar Air fan coil feature icon for auxiliary contact dampers

2 x 24V auxiliary contacts for ERVS or dampers

Polar Air fan coil feature icon for Building Management System (BMS) compatibility

Building Management Systems (BMS) compatible via Modbus

Auto Dynamic Balancing System (ADBS) technology logo for indoor climate control

Auto-Dynamic Balancing System with constant ΔT management

Polar Air fan coil feature icon for control of up to 255 units

255 units group control via ModBus

Polar Air fan coil feature icon for control of up to 32 units

32 units group control via Wired Wallpad

Exclusively developed by Polar Air for intelligent control that includes our ADBS technology for ΔT management and group control. Configuration for 2- and 4-pipe models.

Available through ModBus, or compatible with Polar Air Wired Wallpad or Infrared Handset.

Polar Air fan coil feature icon for programming

24/7 programming

Automatic three speed fan function of Polar Air fan coils.

Auto & 3-Speed functions

Polar Air fan coil feature icon for sleep mode

Sleep function

Polar Air fan coil feature icon for auto restart

Auto-Restart function

Polar Air fan coil feature icon for dehumidification and latent cooling

Dehumidification mode

Polar Air fan coil feature icon for adjustable swing louver

Adjustable swing louver positioning

Polar Air fan coil feature icon for condensate pump

Condensate drain pump control

Polar Air fan coil feature icon for error diagnostics

Error diagnostics on unit LED display or Wired Wallpad

Polar Air fan coil feature icon for integrated valves

Valve control

Polar Air fan coil feature icon for dry contact on off control

Dry contact for On/Off applications

Polar Air fan coil feature icon for electric heater

Electric heater control

Polar Air fan coil feature icon for auxiliary contact dampers

2 x 24V auxiliary contacts for ERVS or dampers

Polar Air fan coil feature icon for Building Management System (BMS) compatibility

Building Management Systems (BMS) compatible via Modbus

Auto Dynamic Balancing System (ADBS) technology logo for indoor climate control

Auto-Dynamic Balancing System with constant ΔT management

Polar Air fan coil feature icon for control of up to 255 units

255 units group control via ModBus

Polar Air fan coil feature icon for control of up to 32 units

32 units group control via Wired Wallpad

Simple yet flexible functionality that is easy to use, allowing for limited LED diagnostics and RPM configuration. Available for 2- and 4-pipe models.

Compatible with external thermostats from a variety of manufacturers.

Polar Air fan coil feature thermostat compatibility

Choose your own external thermostats

Polar Air fan coil feature icon for selectable RPM settings

Configure the motor RPMs to your choice

Polar Air fan coil feature icon for alarm contact

Contact alarm for condensate drain pump and motor

Polar Air fan coil feature icon for error diagnostics

Limited error diagnostics on unit LED display or Wired Wallpad

Project applications & references

Explore recommended applications and recent projects where it’s been successfully installed.

Healthcare

Hospitals · Clinics · Nursing Homes · Treatment Centers · Laboratories · Morgues

Educational

Academies · Schools · Universities · Colleges · Libraries · Campus Buildings

Commercial

Supermarkets · Shopping Malls · Gyms/Sports Facilities · Museums/Theaters/Galleries · Airports & Transport Terminals

Business

Offices · Data Server Rooms · Banks · Call Centers · Showrooms

Our PASELECT Software is specifically designed to help users choose the most suitable Polar Air fan coils for any project.

Downloads: IOMs, Revits & Guide Specs

Access product resources including installation and operation manuals (IOMs), Revit files, and guide specifications.

protected

Revit Files: PCGH-3R_4-pipe

|Size: 4 MB - EN

protected

Revit Files: PCGH-3R_2-pipe

|Size: 4 MB - EN

protected

IOM: PCGH-3R 4-Way Cassette_METRIC_EC Motor

|Size: 5 MB - EN



protected

Revit Files: PCGH-3R_4-pipe

|Size: 4 MB - EN

protected

Revit Files: PCGH-3R_2-pipe

|Size: 4 MB - EN

protected

IOM: PCGH-3R 4-Way Cassette_IMPERIAL_EC Motor

|Size: 11 MB - EN



3D Model

View our 3D models with Sketchfab, click and drag to explore the unit from all angles.

Our trusted network of authorized representatives ensures you receive exceptional customer service and product availability worldwide.

FAQs: cassettes

Determining the right capacity for your cassette fan coil unit is crucial for achieving optimal comfort and efficiency.

The best way to find the perfect fit for your space is by using Polar Air PASELECT software. This innovative tool helps users design their ideal HVAC system by calculating multiple configurations tailored to their specific needs.

The PCGH-3R is offered as a complete package, including an internal/external drain pan, 5 mm (0.2”) NBR insulation, integrated Sauermann condensate pump, manual air vent + water purge valve and G2 (MERV 4) filter. Plus, there are compatible accessories also available.

Installing a cassette fan coil requires a suitable ceiling space with enough depth to house the unit. The process includes mounting the cassette securely, connecting it to the chilled/hot water supply and return lines, and ensuring proper condensate drainage with the integrated pump. Electrical wiring is connected to the control system, and the unit’s louvers and panel are fitted. Once installed, the system is pressure-tested, the airflow is balanced, and controls are configured.

Proper installation ensures efficient operation, easy access for servicing, and long-term reliability.

Yes, cassette fan coil units require regular maintenance to ensure optimal performance and longevity. Routine maintenance tasks include cleaning or replacing the air filters, checking the condensate pump and drain for blockages, and inspecting the coil and fan for dust or debris buildup.

Regular maintenance helps prevent potential issues, improves energy efficiency, and ensures the unit operates effectively. It’s recommended to schedule professional maintenance at least once a year to keep your cassette fan coil unit in top condition and to address any minor problems before they become major issues.

A cassette fan coil is an HVAC unit mounted flush with the ceiling, leaving only the panel visible for a neat, space-saving design. It combines a fan and a water coil to circulate air, heating or cooling it before distributing it back into the room through one, two, three, or four outlets. This design provides efficient temperature control, even air circulation, and helps improve indoor air quality by filtering dust, odors, and excess moisture.

Cassette fan coils are widely used in healthcare, commercial, education, and office buildings for reliable comfort.

The PCGH-3R 4-Way Cassette fan coil units use hydronic (water-based) technology within the unit. Learn more about why Polar Air believes in hydronic systems here.